SPECIFICATIONSGST-9602
|
Load cell excitation |
12 VDC±5% |
Load current |
280 mA (max.) 8 (350)ohm load cells max. |
Input sensitivity |
0.6 uV/ D to 120 uV/ D |
Zero adj. range |
0.35 mV to 24 mV |
Span adjustment |
Full digital calibration |
Input impedance |
10 MΩ |
Display resolution |
10,000 |
A/ D resolution |
100,000 counts |
A/ D conv. rate |
70 times/ sec |
A/ D conversion methodM |
3 phase tare integrating dual-slop type |
Non linearity |
+0.01% of full scale |
Temp. coefficent |
zero…±(0.2 uV±0.0008% of the initial offset voltage)oC span …±5 ppm/ oC of reading |
Power source |
100, 110, 220, 240 50/60 Hz (factory installation) |
Net weight |
approx. 4.0 kg |
Operating temperature |
-5 o C to +40oC |
Operation humidity |
95% RH max. (non-condensing) |
Dimensions (mm) |
250 x 210 x 131 |
Panel cutout dimensions |